HEAVY DUTY UPS 2350-vTURBO 24V DG
- Weight17.7kg
- Output VoltageSame as INPUT
- Dimensions (L*W*H)42.5x45.1x21.5
SALIENT FEATURES:
Heavy Duty UPS Series is a High Torque Performance UPS Series Which is specially designed to handle heavy loads easily.
- Micro Controller Based Intelligent Control Design.
- LED Display Indications (Status & Fault)
- CCCV Technology with Auto Trickle Mode
- Smart Overload Sense and Short Circuit Protection
Microtek Heavy Duty Advanced Digital UPS Model 2350 (24V) DG for Better Performance. The Models in this Series have Bigger Transformer for Better Performance and which Charges the Battery on Low Voltage (Even low as 90V) also. It is designed using latest state-of-the art Technology. It also comes with Additional Features like Super-Fast Charging for Frequent Power cuts, More Backup for Long Power cuts, More Battery Life for Low Running Cost and More Load for Longer Duration.
Rated Capacity | 2000 VA / 24V |
Output Power | 1600 Watts |
Battery | 2 Battery System (24 VDC) |
Waveform | Sinewave |
Warranty | 2 Years |
Microtek Heavy Duty Advanced Digital UPS Model 2350 (24V) DG for Better Performance. The Models in this Series have Bigger Transformer for Better Performance and which Charges the Battery on Low Voltage (Even low as 90V) also. It is designed using latest state-of-the art Technology. It also comes with Additional Features like Super-Fast Charging for Frequent Power cuts, More Backup for Long Power cuts, More Battery Life for Low Running Cost and More Load for Longer Duration.
Rated Capacity | 2000 VA / 24V |
Output Power | 1600 Watts |
Battery | 2 Battery System (24 VDC) |
Waveform | Sinewave |
Warranty | 2 Years |
- Micro Controller Based Intelligent Control Design.
- LED Display Indications (Status & Fault)
- CCCV Technology with Auto Trickle Mode
- Smart Overload Sense and Short Circuit Protection
- Battery State Monitoring
- Multi Stage Battery Charger
- Mains Input Voltage Range Slide Selection Switch
DISPLAY
- MAINS ON
- UPS ON
- BATTERY CHARGING
- OVERLOAD
- BATTERY LOW
- FAULT INDICATION
MODEL | HEAVY DUTY 2350 (24V) DG |
---|---|
INPUT | |
INPUT VOLTAGE (Standard range) | 90V ~ 300V |
INPUT VOLTAGE (Narrow Range) | 180V ~ 260V |
OUTPUT | |
OUTPUT VOLTAGE (Main Mode) | Same as INPUT |
OUTPUT VOLTAGE (UPS Mode) | 200V ~ 230V + 10% |
OUTPUT WAVE FROM (Main Mode) | Same as INPUT |
OUTPUT WAVE FROM (UPS Mode) | TPZi (Trapezoidal Waveform) |
CHANGE-OVER | |
SWITCHOVER (Mains>UPS / UPS>Mains) | AUTOMATIC |
UPS TRANSFER TIME | <15msec |
TECHNOLOGY | |
DESIGN | Micro Controller Based Design With IPS Technology |
BATTERY CHARGING CURRENT | 10% of the Rated Battery Current in AH |
UPS OVERLOAD / UPS SHORT CIRCUIT | 110% / 300% |
BROWNS ON MAINS VOLTAGE | 100V +40V |
EFFICIENCY (BATTERY MODE) | >84% |
AUTO RESET FEATURE | YES |
INPUT DC RANGE | 21V ~ 28.4V |
CHARGING CURRENT (Standard) | 12 Amps +1 Amps |