Energy Saver Pure Sinewave UPS Model 1225 (12V) SW
- Weight9.9kg
- Output VoltageSame as INPUT
- Dimensions (L*W*H)38.7x39.6x20.7
SALIENT FEATURES:
- Micro Controller Based Intelligent Control Design.
- LED Display Indications for UPS Status and Fault
- CCCV Technology with Auto Trickle Mode
- Smart Overload Sense and Short Circuit Protection
- Battery State Monitoring
MICROTEK Energy Saver Pure Sinewave UPS Model 1225 (12V) SW is Micro Controller design based, LARGEST SELLING SERIES of Extended Backup External Battery UPS Systems. It comes with many user friendly features. It has Voltage Range Selection Switch and can be operated in Standard Voltage Range from 100V~300V and Narrow Voltage Range from 180V~260V. UPS Energy Saver Pure Sinewave UPS Series Models are based on Intelli Pure Sinewave Technology which ensures Noiseless, Safe and Efficient Performance along with Longer Backup.
MICROTEK Energy Saver Pure Sinewave UPS Model 1225 (12V) SW is Micro Controller design based, LARGEST SELLING SERIES of Extended Backup External Battery UPS Systems. It comes with many user friendly features. It has Voltage Range Selection Switch and can be operated in Standard Voltage Range from 100V~300V and Narrow Voltage Range from 180V~260V. UPS Energy Saver Pure Sinewave UPS Series Models are based on Intelli Pure Sinewave Technology which ensures Noiseless, Safe and Efficient Performance along with Longer Backup.
- Micro Controller Based Intelligent Control Design.
- LED Display Indications for UPS Status and Fault
- CCCV Technology with Auto Trickle Mode
- Smart Overload Sense and Short Circuit Protection
- Battery State Monitoring
- Multi Stage Battery Charger
- Mains Input Voltage Range Slide Selection Switch
- Battery Slide Selection Switch (Local/Flat/Tubular)
DISPLAY
- MAINS ON
- UPS ON
- BATTERY CHARGING
- OVERLOAD
- BATTERY LOW
- FAULT INDICATION
MODEL | ENERGY SAVER 1225 (12V) SW |
---|---|
INPUT | |
INPUT VOLTAGE (Standard range) | 100V ~ 300V |
INPUT VOLTAGE (Narrow Range) | 180V ~ 260V |
OUTPUT | |
OUTPUT VOLTAGE (Main Mode) | Same as INPUT |
OUTPUT VOLTAGE (UPS Mode) | 200V ~ 230V + 10% |
OUTPUT WAVE FROM (Main Mode) | Same as INPUT |
OUTPUT WAVE FROM (UPS Mode) | Pure Sinewave |
CHANGE-OVER | |
SWITCHOVER (Mains>UPS / UPS>Mains) | AUTOMATIC |
UPS TRANSFER TIME | <15msec |
TECHNOLOGY | |
DESIGN | Micro Controller Based Design With IPS Technology |
BATTERY CHARGING CURRENT | 10% of the Rated Battery Current in AH |
UPS OVERLOAD / UPS SHORT CIRCUIT | 110% / 300% |
BROWNS ON MAINS VOLTAGE | 100V +40V |
EFFICIENCY (BATTERY MODE) | >80% |
AUTO RESET FEATURE | YES |
INPUT DC RANGE | 10.5V ~ 14.2V |
CHARGING CURRENT (Standard) | 10 Amps +1 Amps |
CHARGING CURRENT (High) | 14 Amps +1 Amps |